Synchronized Mode
1 MASTER Choose same as manual, automatic, sound-controlled mode
2 SLAVE
DMX Setting
Enter a DMX address with the arrows on the display. Confirm and save with ENTER.
3-Channel Mode
Channel Function From To Description
1 Red 0 255 From 0 ~ 100 %
2 Green 0 255 From 0 ~ 100 %
3 Blue 0 255 From 0 ~ 100 %
7-Channel Mode
Channel Function From To Description
1 Red – 1 0 255 From 0 ~ 100 %
2 Green – 1 0 255 From 0 ~ 100 %
3 Blue – 1 0 255 From 0 ~ 100 %
4 Red – 2 0 255 From 0 ~ 100 %
5 Green – 2 0 255 From 0 ~ 100 %
6 Blue – 2 0 255 From 0 ~ 100 %
7 Master DIMMER 0 255 From 0 ~ 100 %
DMX512 Connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-
pin XLR input of the VDPLOW3601. Multiple VDPLOW3601s can be linked through serial linking. The linking cable
should be a two-core screened cable with XLR input and output connectors.
DMX512 Chain with Termination
A DMX terminator is recommended for installations where the DMX cable has to run a
long distance or is in an electrically noisy environment (e.g. discos). The terminator
prevents corruption of the digital control signal by electrical noise. The DMX terminator is
simply an XLR plug with a 120 resistor between pins 2 and 3, which is then plugged into
the XLR output socket of the last device in the chain.
Please see illustrations.
DMX Start Address
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This start
address is the channel number from which the device starts to “listen” to the DMX controller. Enter the correct
number and read it from the display located on the base of the VDPLOW3601.
You can use the same starting address for a whole group of devices or enter an individual one for every device.
When all devices have the same address, all the VDPLOW3601s will “listen” to the control signal on one particular
channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you set